Evaluation of a Perspex Positioning Device on Post Operative Imaging Following Total Knee Replacement (TKR)

McLeod-Mills L and Hau RC

Background: Post-operative imaging is important in the evaluation of the success of a total knee replacement (TKR). The Orthopaedic surgeon uses post-operative imaging to assess sizing and sagittal and coronal alignments of the prosthesis. Poor radiographic technique can hinder this evaluation and in some cases patients require additional imaging prior to discharge which has resource and cost implications.

This is a combined Radiology and Orthopaedic quality assurance project.

Aim: The aim of this project is to evaluate the effect of a new positioning device on the quality of immediate post-operative imaging of patients who have undergone a TKR.

Methodology: In January 2012 the Radiology department introduced a new positioning device. The device allows radiographers to obtain required images without repositioning the patient between views and provides improved patient comfort. Improved positioning and patient comfort in combination with a simple marking technique allows radiographers to make small changes to correct rotation or tilt.

Two senior radiographers reviewed the immediate post-operative examinations performed on patients who underwent TKR at The Northern Hospital between July 2011 and June 2012. The images were categorised as good, acceptable and requires re-imaging.

Results: A total of 69 examinations prior to the introduction of the new device and 46 examinations following the introduction were reviewed. Prior to the introduction of the device 74% (51) anterior-posterior (AP) images and 88% (60) lateral images were rated as good-acceptable. These results increased to 87% (40) for AP images and 96% (44) for lateral images following the introduction of the new device.

Conclusion: The introduction of the new positioning device has resulted in an overall improvement in the quality of the post-operative imaging following TKR.